Recognised Practitioners RPP (Ex01R-04R)

Course Information

8:00 AM -5:00 PM.

+65 8966 7512

+65 9237 8012

enquiry@atts-asia.com

  1. Updates in Standards, Certification and marking.
  2. Review of the nature of flammable materials including ignition temperature, gas/equipment grouping, temperature classification, ambient temperature ratings, equipment protection levels; and ingress protection and area classification
  3. Types of protection Ex d, Ex e, Ex n, Ex p, Ex i; and hybrids
  4. Selection of installation of cables, glands and accessories to IEC 60079-14 in test rigs.
  5. Inspection of equipment to IEC 60079-17 – visual, close, and detailed grades of inspection in test rigs.
  6. Selection & Installation of non I.S & I.S equipment to minimum requirements on simulated board.

Course duration
2 days

Assessment
Assessment is undertaken using both practical assessments and an online examination that covers the four separate CompEx units.
Theoretical: 20MCQ
Practical: candidates are required to undertake 4 practical assessments
Ex01R – Glanding & Installation (no barrier gland)
Ex02R – Inspection of Non. I.S equipment
Ex01R & Ex03R – Selection & Installation of Non I.S & I.S equipment using simulated board online
Ex04R – Inspection of I.S equipment

The course is intended to refresh and update the knowledge and skills of qualified Electrical & Instrumentation Personnel working with electrical equipment for hazardous areas. Competency assessment will be conducted on test rigs and simulated boards to cover updates in installation practices and inspections for power and intrinsically safe equipment. Compliance with the latest editions of IEC 60079 for electrical equipment in explosives atmospheres is an essential element of the course. Knowledge will be assessed with multi-choice questions through on-line examination.

Certification
Certificate of Core Competency (Refresher) by CompEx Certification Limited (CCL) valid for 5 years.

Personnel who hold a current CompEx Certificate of Core Competence in modules Ex01, Ex02, Ex03 and Ex04 are eligible for this course.

Applicants should possess the assumed skills and knowledge as outlined in the competency standards as follows:

  1. Must have good standards of both written and verbal English
  2. Possess Electrical/Instrumentation qualification from the vocation schools that enable us to determine the electrotechnical competence
  3. Possess Employment certification (clearly indicate the electrical/instrumentation work experience in the recent years)
  4. A valid CompEx competency certification

Application procedure

CompEx Course Registration Process:

  1. All delegates are required to register directly via the CompEx portal prior to application.
  2. Self Registration on the CompEx portal (https://registration.compexcertification.com/)
  3. The delegates will be given a ULN Number for course registration.
  4. Upon application, please provide the ULN Number.

All applications are to be submitted (with full documentation) via email (enquiry@atts-asia.com) at least 7 working days prior to course commencing date. Successful applicants will receive the course confirmation and payment advisory email. Registration is only confirmed upon full payment of course fees.

Important Reminders:

  • Delegates are required to bring their own Personal Protective Equipment (PPE), including Coveralls, Safety goggles, Hand gloves & Safety shoes.
  • Kindly note that participation in the practical activity is subject to having the appropriate PPE. The training centre reserves the right to restrict participation if proper PPE is not worn.
  • Delegates are required to bring a valid photographic identification for verification purposes. (e.g. Passport, Driving license, or any other official photo identification.)
  • Failure to present a valid ID may result in denied entry to the course or assessment.